TA Series

TAS-Loop-Powered Transmitter
With DC 24V loop power 

FEATURES:

◆DC 4~20mA input with DC 24V loop power
◆4 digits display:-1999~9999 Count
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAS-Loop-Powered Transmitter
With DC 24V loop power 

FEATURES:

◆DC 4~20mA input with DC 24V loop power
◆4 digits display:-1999~9999 Count
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC systems. This allows for signal isolation between the instruments and DCS/PLC, eliminating ground common-mode noise and improving system stability. This product series also provides DC 24V voltage output to power two-wire devices in the front-end loop. The series offers multiple configurations, including one input and one output, one input and two outputs, and various other combinations.

TAS2-Loop-Powered Transmitter Dual Outputs
With DC 24V loop power

FEATURES:

◆DC 4~20mA input with DC 24V loop power
◆4 digits display:-1999~9999 Count
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAS2-Loop-Powered Transmitter Dual Outputs
With DC 24V loop power

FEATURES:

◆DC 4~20mA input with DC 24V loop power
◆4 digits display:-1999~9999 Count
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAD-DC Signal Transmitter
With split-core CT(optional)  

FEATURES:

◆DC current/voltage and AC current(with split-core CT)
◆4 digits display:-1999~9999 Count
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAD-DC Signal Transmitter
With split-core CT(optional)  

FEATURES:

◆DC current/voltage and AC current(with split-core CT)
◆4 digits display:-1999~9999 Count
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAD2-DC Signal Transmitter Dual Outputs
With split-core CT(optional)

FEATURES:

◆DC current/voltage and AC current(with split-core CT)
◆4 digits display:-1999~9999 Count
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAD2-DC Signal Transmitter Dual Outputs
With split-core CT(optional)

FEATURES:

◆DC current/voltage and AC current(with split-core CT)
◆4 digits display:-1999~9999 Count
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAP-Potentiometer Transmitter 

FEATURES:

◆Input signal: 0~10KΩ
◆4 digits display:-1999~9999 Count
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAP-Potentiometer Transmitter 

FEATURES:

◆Input signal: 0~10KΩ
◆4 digits display:-1999~9999 Count
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAP2-Potentiometer Transmitter Dual Outputs 

FEATURES:

◆Input signal: 0~10KΩ
◆4 digits display:-1999~9999 Count
◆Dual analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAP2-Potentiometer Transmitter Dual Outputs 

FEATURES:

◆Input signal: 0~10KΩ
◆4 digits display:-1999~9999 Count
◆Dual analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAR-RTD Temperature Transmitter

FEATURES:

◆Input signal: PT 100Ω 3wire -100~400℃
◆Display range:-100~400℃/-100~700℉
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAR-RTD Temperature Transmitter

FEATURES:

◆Input signal: PT 100Ω 3wire -100~400℃
◆Display range:-100~400℃/-100~700℉
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAR2-RTD Temp. Transmitter Dual Outputs

FEATURES:

◆輸入信號4位數字顯示-100.0 ~400.0
◆數字顯示-100~400℃/-100~700℉
◆輸入/輸出/電源之間隔離(2KV AC)
◆超薄外型設計,不占空間
◆高精度等級(0.1% F.S)
◆高線性度(0.1% F.S.

TAR2-RTD Temp. Transmitter Dual Outputs

FEATURES:

◆Input signal: PT 100Ω 3wire -100~400℃
◆Display range:-100~400℃/-100~700℉
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAT-Thermocouple Transmitter  

FEATURES:

◆Selectable input type: K / E / J / R / S / B Type
◆Display range:-1999 ~9999
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAT-Thermocouple Transmitter  

FEATURES:

◆Selectable input type: K / E / J / R / S / B Type
◆Display range:-1999 ~9999
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAT2-Thermocouple Transmitter Dual Outputs

FEATURES:

◆Selectable input type: K / E / J / R / S / B Type
◆Display range:-1999 ~9999
◆2 Relay ouptuts with programmable delaytime and deadband
◆Analog output:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S

TAT2-Thermocouple Transmitter Dual Outputs

FEATURES:

◆Selectable input type: K / E / J / R / S / B Type
◆Display range:-1999 ~9999
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.

TAG-DC Signal to Frequency Transmitter 

FEATURES:

◆4 Digits Display For Input Signal:-1999~9999
◆Input Range:10HZ~100K
◆Programmable Display Value And Alarm Point
◆OutputFrequency:Open Collect NPN,PNP / Relay Contact / Voltage Pulse
◆Ultra-thin Dimension,27mm width
◆Non-Combustible PC Case .DIN Rail or Wall Mounting
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )

TAG-DC Signal to Frequency Transmitter 

FEATURES:

◆4 Digits Display For Input Signal:-1999~9999
◆Input Range:10HZ~100K
◆Programmable Display Value And Alarm Point
◆OutputFrequency:Open Collect NPN,PNP / Relay Contact / Voltage Pulse
◆Ultra-thin Dimension,27mm width
◆Non-Combustible PC Case .DIN Rail or Wall Mounting
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )


The TA series is a display isolator that provides 2 relay outputs, with the option to add an additional analog output. It features digital settings, allowing you to customize the display, input, output, and scaling ratios. The relays can be configured with delay alarms or non-action zones, making it highly convenient for on-site use.
In industrial automation systems, signals from field instruments are isolated and transmitted to DCS/PLC, enabling signal isolation between the instruments and DCS/PLC. This helps eliminate ground common-mode noise and enhances system stability.