TWS/TWS2-Loop-Powered Transmitter
With DC 24V loop power
FEATURES:
◆DC 4~20mA input with DC 24V loop power
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
TWS/TWS2-Loop-Powered Transmitter
With DC 24V loop power
FEATURES:
◆DC 4~20mA input with DC 24V loop power
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
The TWx series isolator is used in industrial automation systems to receive signals from field instruments, which are then isolated and transmitted to DCS/PLC. It ensures signal isolation between instruments and DCS/PLC, eliminating ground loop noise and improving system stability. This series also provides a DC24V output to supply power to two-wire loop devices. The series offers multiple configurations, including one input and one output, one input and two outputs, and two inputs and two outputs.
TWD/TWD2-DC Signal Transmitter
FEATURES:
◆Input DC current/voltage
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
TWD/TWD2-DC Signal Transmitter
FEATURES:
◆Input DC current/voltage
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
The TWx series isolator is used in industrial automation systems to receive signals from field instruments, which are then isolated and transmitted to DCS/PLC. It ensures signal isolation between instruments and DCS/PLC, eliminating ground loop noise and improving system stability. This series offers multiple configurations, including one input and one output, one input and two outputs, and two inputs and two outputs.
TW2S-Loop-Powered Transmitter
With dual inputs&outputs /DC 24V loop power
FEATURES:
◆Dual inputs and outputs
◆DC 4~20mA input with DC 24V loop power
◆Analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
TW2S-Loop-Powered Transmitter
With dual inputs&outputs /DC 24V loop power
FEATURES:
◆Dual inputs and outputs
◆DC 4~20mA input with DC 24V loop power
◆Analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
The TWx series isolator is used in industrial automation systems to receive signals from field instruments, which are then isolated and transmitted to DCS/PLC. This process ensures signal isolation between instruments and DCS/PLC, eliminating ground loop noise and enhancing system stability. Additionally, this series provides a DC 24V output voltage for powering upstream two-wire devices.
TW2D-DC Signal Transmitter
With dual inputs&outputs
FEATURES:
◆Dual inputs and outputs
◆Analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
TW2D-DC Signal Transmitter
With dual inputs&outputs
FEATURES:
◆Dual inputs and outputs
◆Analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
The TWx series isolator is used in industrial automation systems to receive signals from field instruments, which are then isolated and transmitted to DCS/PLC. This enables signal isolation between the instruments and DCS/PLC, effectively eliminating ground loop noise and enhancing system stability.
TWR/TWR2-RTD Temperature Transmitter
FEATURES:
◆Input signal: PT 100Ω 3wire -100~400℃
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
TWR/TWR2-RTD Temperature Transmitter
FEATURES:
◆Input signal: PT 100Ω 3wire -100~400℃
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
The TWx series isolator is used in industrial automation systems to receive signals from field instruments, which are then isolated and transmitted to DCS/PLC. This ensures signal isolation between the field instruments and DCS/PLC, eliminating ground loop noise and improving system stability. This series of products can also output DC24V voltage to power two-wire devices in the front stage. This series offers various combinations, including one-in-one-out, two-in-two-out, and two-in-two-out options.
TWP/TWP2-Potentiometer Transmitter
FEATURES:
◆Input DC current/voltage
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
TWP/TWP2-Potentiometer Transmitter
FEATURES:
◆Input signal: 0~10KΩ
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
The TWx series isolator is used in industrial automation systems to receive signals from field instruments, which are then isolated and transmitted to DCS/PLC. It ensures signal isolation between instruments and DCS/PLC, eliminating ground loop noise and improving system stability. This series offers multiple configurations, including one input and one output, one input and two outputs, and two inputs and two outputs.
TWF / TWF2 轉速/線速/頻率訊號轉換器
FEATURES:
◆ NPN,PNP, 電壓脈衝, 弦波訊號30~600Vp
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆高精度等級(0.1% RO)
◆高線性度(0.1% RO)
◆低溫度漂移(35PPM/℃)
TWF/TWF2-Frequency To DC Signal Transmitter
FEATURES:
◆Input: NPN,PNP, voltage pulse,relay contact
◆One or two analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆High Dielectric Strength ( AC 2KV/Min,Input / Output / Power )
◆Small size (Depth< 90mm)
◆High accuracy: ±0.1% F.S
The TWx series isolator is used in industrial automation systems to receive signals from field instruments, which are then isolated and transmitted to DCS/PLC. It ensures signal isolation between instruments and DCS/PLC, eliminating ground loop noise and improving system stability. This series offers multiple configurations, including one input and one output, one input and two outputs, and two inputs and two outputs.