MMV-AC Voltage Digital Meter
FEATURES:
◆5 digits display:-19999~99999 Count
◆Programmable PT ratio
◆Dual RS485 Modbus RTU
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆4 relays outputs with programmable delaytime and deadband
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
◆High accuracy: 0.15% FS
◆True RMS measurement(optional)
MMV-AC Voltage Digital Meter
FEATURES:
◆5 digits display:-19999~99999 Count
◆Programmable PT ratio
◆Dual RS485 Modbus RTU
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆4 relays outputs with programmable delaytime and deadband
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
◆High accuracy: 0.15% FS
◆True RMS measurement(optional)
MMA-AC Current Digital Meter
FEATURES:
◆5 digits display:-19999~99999 Coun
◆Programmable CT ratio
◆Dual RS485 Modbus RTU
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆4 relays outputs with programmable delaytime and deadband
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
◆High accuracy: 0.15% FS
◆True RMS measurement(optional)
◆Split-core CT (optional)
MMA-AC Current Digital Meter
FEATURES:
◆5 digits display:-19999~99999 Coun
◆Programmable CT ratio
◆Dual RS485 Modbus RTU
◆Dual analog outputs:0-20mA/4-20mA or 0-5V/1-5V/0-10V
◆4 relays outputs with programmable delaytime and deadband
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
◆High accuracy: 0.15% FS
◆True RMS measurement(optional)
◆Split-core CT (optional)
MMF-Frequency Digital Meter
FEATURES:
◆Measures up to 400HZ
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆2 Relay ouptuts with programmable delaytime and deadband
MMF-AC Frequency Digital Meter
FEATURES:
◆Measures up to 400HZ
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆2 Relay ouptuts with programmable delaytime and deadband
MMPF-Power Factor Digital Meter
FEATURES:
◆Measurement range: -0.1~1~+0.1 COSØ
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: -32768~32767
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆2 Relay ouptuts with programmable delaytime and deadband
MMPF-Power Factor Digital Meter
FEATURES:
◆Measurement range: -0.1~1~+0.1 COSØ
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: -32768~32767
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆2 Relay ouptuts with programmable delaytime and deadband
MMW-Watt Digital Meter
FEATURES:
◆Display range: -32768~32767
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆TRMS smpling,128 sections per cycle
◆Bi-directional measurement
◆Dual RS485 Modbus RTU
◆DC 4~20mA ouptut
◆2 Alarm settings
◆Programmable PT and CT ratio
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
MMW-Watt Digital Meter
FEATURES:
◆Bi-directional measurement
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: -32768~32767
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆2 Relay ouptuts with programmable delaytime and deadband
◆Split-core CT (optional)
MMQ-Var Digital Meter
FEATURES:
◆Display range: -32768~32767
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆TRMS smpling,128 sections per cycle
◆Bi-directional measurement
◆Dual RS485 Modbus RTU
◆DC 4~20mA ouptut
◆2 Alarm settings
◆Programmable PT and CT ratio
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
MMQ-Var Digital Meter
FEATURES:
◆Bi-directional measurement
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: -32768~32767
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆2 Relay ouptuts with programmable delaytime and deadband
◆Split-core CT (optional)
MMWH-Watthour Digital Meter
FEATURES:
◆Display range: ±99999999 KWH
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆TRMS smpling,128 sections per cycle
◆Bi-directional measurement
◆Dual RS485 Modbus RTU
◆DC 4~20mA ouptut
◆2 Alarm settings
◆Programmable PT and CT ratio
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
MMWH-Watthour Digital Meter
FEATURES:
◆Bi-directional measurement
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: ±99999999 WH
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Dual pulse outputs
◆Split-core CT (optional)
MMQH-Varthour Digital Meter
FEATURES:
◆Display range: ±99999999 KWH
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆TRMS smpling,128 sections per cycle
◆Bi-directional measurement
◆Dual RS485 Modbus RTU
◆DC 4~20mA ouptut
◆2 Alarm settings
◆Programmable PT and CT ratio
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
MMQH-Varhour Digital Meter
FEATURES:
◆Bi-directional measurement
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: ±99999999 VARH
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Dual pulse outputs
◆Split-core CT (optional)
MMWH-Watt / Watthour Digital Meter
FEATURES:
◆Display range: ±99999999 KWH
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆TRMS smpling,128 sections per cycle
◆Bi-directional measurement
◆Dual RS485 Modbus RTU
◆DC 4~20mA ouptut
◆2 Alarm settings
◆Programmable PT and CT ratio
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
MMWWH-Watt / Watthour Digital Meter
FEATURES:
◆Bi-directional measurement
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: -32768~32767 Watt / ±99999999 Watthour
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆Dual pulse outputs
◆Split-core CT (optional)
MMWH-Var / Varhour Digital Meter
FEATURES:
◆Display range: ±99999999 KWH
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆TRMS smpling,128 sections per cycle
◆Bi-directional measurement
◆Dual RS485 Modbus RTU
◆DC 4~20mA ouptut
◆2 Alarm settings
◆Programmable PT and CT ratio
◆Selectable sampling speed: (High/Medium/Low)
◆Small size (Depth< 90mm)
MMQQH-Var / Varhour Digital Meter
FEATURES:
◆Bi-directional measurement
◆Suitable for: 1∮2W / 1∮3W / 3∮3W / 3∮4W
◆Display range: -32768~32767 Var / ±99999999 Varhour
◆Programmable PT and CT ratio
◆RS485 Modbus RTU
◆Analog output:DC 4-20mA
◆Dual pulse outputs